Publikationen

Liste Gitter

DWA-M 153 - Action for Dealing Stormwater (8/2007)

This DWA-Guideline includes recommendations how to treat rainwater quantitatively and qualitatively in modified drainage patterns or serperate sewerage systems. It analyzes and structures complexe correlations as follows: - pollution and quantity of rainwater regarding to utilisation and pavement of origin surface, - protection requirement of groundwater, - protection requireme... Mehr erfahren

42,00 €
inkl. MwSt.

DWA-A 161E - Static calculation (3/2014)

The standard was published in May 2018, based on the German edition of March 2014 in the corrected version of October 2017. This standard applies to the structural calculation of pipes with a circular cross-section which are installed according to the pipe jacking method in a straight or bending direction in non-cohesive or cohesive soils (loose soils as according to DIN 18319) with static force ... Mehr erfahren

84,50 €
inkl. MwSt.

DWA-M 180E - Real Time Control (12/2005)

The Advisory Leaflet introduces the basic aspects of real time control to potential users and presents a sound level of knowledge to those planners, operators and administrations involved in the development of real time control systems. It aims to achieve the use of real time control as a potential alternative on a regular basis in future planning of drainage schemes. This includes simple local co... Mehr erfahren

46,00 €
inkl. MwSt.

ATV-DVWK-A 198 - Standardisation (4/2003)

This Standard is concerned with the definition, collection, evaluation and examination of data as well as with the subsequent derivation of dimensioning values based on these for wastewater treatment plants and drainage systems. Forecast data for various time horizons can subsequently be derived from measured data. With this Standard the objective is pursued, globally for all DWA Standards and Adv... Mehr erfahren

40,50 €
inkl. MwSt.

DWA-A 199-1 - Operating Instructions (11/2011)

Operators of wastewater facilities shall establish service and operating instructions tailored to their respective circumstances in order to adhere to the requirements especially of § 57 of the German Water Resources Management Law (WHG) and in order to meet the minimum requirements of the self-inspection or self-monitoring ordinances of Germany's federal states. Since the regulatory content of t... Mehr erfahren

35,50 €
inkl. MwSt.

ATV-A 200 - Wastewater Rurally Areas (5/1997)

This Standard indicates possibilities for the economic realisation of an ordered disposal of wastewater in rurally structured regions. However, with all the currently discussed measures for cost reduction, the actual aims, protection of lakes and rivers and safety of local hygiene may not be placed in jeopardy. Wastewater treatment plants in rurally structured areas should not be planned, built an... Mehr erfahren

35,00 €
inkl. MwSt.

DWA-A 272 - New Alternative Sanitation (6/2014)

In recent years, numerous research and demonstration projects have been carried out at national and international level in the field of new urban water infrastructure systems, leading to new insights and technical concepts. Background of this work are in particular the emerging changes in key framework conditions for water infrastructure, including additional requirements from the point of ... Mehr erfahren

44,50 €
inkl. MwSt.

DWA-M 277E - greywater (10/2017)

The urban water management must address new challenges. Examples include the impact of demographic trends and climate changes or the implementation of resource protection measures. New Alternative Sanitation Systems (NASS) represent one potential approach, where technologies are used to close as far as possible the water and material cycles for the purpose of recycling the valuable componen... Mehr erfahren

47,50 €
inkl. MwSt.

ATV-DVWK-A 281 - Trickling Filters (9/2001)

The biological stage of wastewater treatment plants, employing trickling filters and rotating biological contactors without sludge return feed, is dealt with in this Standard. The standard applies only for rotating biological contactors without artificial aeration for the supply of the biofilm with the required oxygen. The development of the trickling filter process and the rotating biological con... Mehr erfahren

28,00 €
inkl. MwSt.

Liste Gitter